Choose a borehole pump pipe by the flow it must carry, its actual inside diameter and the length of the route. Compare the resulting friction loss, then check pressure rating, joints, supported load and installation space. The pump outlet gives you a connection to match, while the rest of the pipework needs its own sizing check.
For an existing installation, start with the pipe markings, material, route length and pump model. A supplier’s dimension table can turn the pipe description into the internal diameter needed for a loss calculation. If you have several pipe sizes along the route, record each section separately.
Find the diameter that water actually flows through
Pipe descriptions can refer to a nominal size or an outside diameter. Inside diameter, or ID, is the bore available for water flow. Wall thickness takes up some of the space inside the outside diameter. Pipe material, pressure class and dimensional standard therefore matter when you identify the bore.
For example, Vinidex’s PE100 table lists a DN32 pipe in its SDR11 column with a mean inside diameter of 26 mm. Its minimum wall thickness is a separate field. Use the manufacturer’s dimension data and tolerances for the selected pipe when you calculate losses. Vinidex PE100 dimension table.
Record the route from the pump to the delivery point, including the downhole rising main and the surface run. A 60 m rising main followed by 40 m of surface pipe gives 100 m of pipe to assess. The pumping water level is used separately to calculate the lift. QDD’s guide to total dynamic head.
Compare two bores at the same flow
Consider an illustrative flow of 3 m³/h, or 50 L/min, through 100 m of straight pipe. Compare actual inside diameters of 25 mm and 32 mm. These are assumed hydraulic bores for the example. To keep the comparison simple, use a Darcy friction factor of 0.025 for both and gravitational acceleration of 9.81 m/s².
The Darcy-Weisbach method calculates straight-pipe head loss from pipe length, internal diameter, velocity and friction factor. In a design calculation, the friction factor depends on the flow regime and pipe roughness. Vinidex’s hydraulic calculation guidance.
Velocity = flow ÷ internal cross-sectional area. Convert the flow to m³/s and the diameter to metres before calculating the area. Here, 3 m³/h is 0.0008333 m³/s, and a circular bore has area π × D² ÷ 4.
Straight-pipe head loss = f × (L ÷ D) × (v² ÷ (2 × g)). In this expression, f is the Darcy friction factor, L is pipe length in metres, D is inside diameter in metres, v is velocity in m/s, and g is gravitational acceleration.
| Actual inside diameter | Result at 3 m³/h over 100 m |
|---|---|
| 25 mm | Velocity 1.70 m/s, straight-pipe loss 14.7 m |
| 32 mm | Velocity 1.04 m/s, straight-pipe loss 4.3 m |

In this example, the larger bore reduces the straight-pipe loss by about 10.4 m of head at the same flow. The result describes the straight pipe under the stated assumptions. Add the losses through bends, valves, fittings and any other equipment in the actual route. If a section has a different bore or material, calculate that section using its own data and add the losses at the common design flow.
Check how the pipe changes the operating point
For the same target flow, delivery elevation and required outlet pressure, reducing pipe loss reduces the head the pump needs to supply. If you keep the existing fixed-speed pump and change the pipe, the actual flow follows the new intersection of the pump and system curves. Check the proposed operating point against the pump’s permitted range and the well’s supply capacity. QDD’s guide to pump curves and duty points.
A larger pipe also changes the space and support needed for the installation. It may contain more water and require larger fittings. Compare the hydraulic benefit with the pipe and joint load limits, the well clearance, the cable route and the proposed support arrangement before ordering.
Check pressure and supported load separately
Ask the supplier to confirm the pipe’s permitted working pressure for the material, temperature and service conditions. The system pressure assessment should cover the maximum pressures at the relevant points, including the pump’s shut-off condition where applicable and pressure transients. Xylem’s submersible-pump installation checklist specifically requires checking pipe pressure rating against pump shut-off pressure. Xylem installation manual, page 2.
Fittings and joints need compatible ratings. For PE pipe, the PE100+ Association relates operating pressure to material, pipe geometry and operating conditions, with temperature taken into account. PE100+ pipe design guidance.
The downhole assembly also carries a mechanical load. Have the installer check the supported pipe, water and equipment loads, together with the joint and support capacities. A rising-main specification may list maximum working pressure and maximum working load as separate limits. Keep those separate in the quotation and installation check. Boreline rising-main specifications.
Check the minimum flow passage through reducers, connectors and valves as well as the straight pipe. Include their losses in the calculation and confirm that their outside dimensions can pass through the installation space. QDD check valves and fittings.
Prepare a pipe-sizing enquiry
Send the target flow and required head, the pump model or curve, and the lengths of the downhole and surface sections. Add the pipe material and markings, the supplier’s inside-diameter data, the main fittings and the delivery arrangement. For a rising main, include the planned setting depth and the support method so the pressure and mechanical checks can be completed together.
Ask for the proposed pipe specification, the calculated loss at your target flow, and the resulting pump duty point in the same recommendation. The installer can then compare the measured delivery with that agreed duty during commissioning. QDD pump selection help.