Home / Borehole pumps / 100GSP series Your application
Kept with your request for context. No model has been selected for you.
Permanent-magnet borehole pumps
100GSP permanent-magnet borehole pumps
Browse the 100GSP series by flow group and the paired head listed for each model. The series uses permanent-magnet motors and stainless-steel impellers; confirm the complete material specification and drive combination for the selected pump.
42
catalogue models
5
flow groups
2.2–22
catalogue-listed kW
100GSP Catalogue reference Exterior Catalogue cutaway
View catalogue cutaway
Model finder
Compare 100GSP models by flow, head and power. 3 · 6 · 10 · 15 · 20 m³/h flow groups. Compare up to 3 models at a time.
Q and H below are the source-catalogue values for each model, not maximum flow and maximum head. P is the catalogue-listed power. Share your required flow, head and power supply if you would like help choosing a model.
All 42 catalogue models are listed below. Enable JavaScript to filter, compare or prepare a shortlist.
42 catalogue models
Q: m³/h · H: m · P: kW
100GSP models and source-catalogue reference values Model / shortlist Q m³/h H m P kW Outlet Details 100GSP3T-105/8 3 105 2.2 1½" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 3 m³/h Catalogue head: 105 m Listed power: 2.2 kW
100GSP3T-167/13 3 167 3 1½" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 3 m³/h Catalogue head: 167 m Listed power: 3 kW
100GSP3T-205/16 3 205 4 1½" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 3 m³/h Catalogue head: 205 m Listed power: 4 kW
100GSP3T-278/21 3 278 5.5 1½" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 3 m³/h Catalogue head: 278 m Listed power: 5.5 kW
100GSP3T-382/29 3 382 7.5 1½" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 3 m³/h Catalogue head: 382 m Listed power: 7.5 kW
100GSP3T-400/32 3 400 11 1½" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 3 m³/h Catalogue head: 400 m Listed power: 11 kW
100GSP3T-489/45 3 489 15 1½" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 3 m³/h Catalogue head: 489 m Listed power: 15 kW
100GSP3T-600/55 3 600 18.5 1½" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 3 m³/h Catalogue head: 600 m Listed power: 18.5 kW
100GSP6T-98/6 6 98 2.2 1½" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 6 m³/h Catalogue head: 98 m Listed power: 2.2 kW
100GSP6T-144/9 6 144 3 1½" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 6 m³/h Catalogue head: 144 m Listed power: 3 kW
100GSP6T-191/12 6 191 4 1½" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 6 m³/h Catalogue head: 191 m Listed power: 4 kW
100GSP6T-255/16 6 255 5.5 1½" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 6 m³/h Catalogue head: 255 m Listed power: 5.5 kW
100GSP6T-350/23 6 350 7.5 1½" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 6 m³/h Catalogue head: 350 m Listed power: 7.5 kW
100GSP6T-478/28 6 478 11 1½" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 6 m³/h Catalogue head: 478 m Listed power: 11 kW
100GSP6T-502/33 6 502 15 1½" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 6 m³/h Catalogue head: 502 m Listed power: 15 kW
100GSP6T-578/38 6 578 18.5 1½" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 6 m³/h Catalogue head: 578 m Listed power: 18.5 kW
100GSP10T-56/4 10 56 2.2 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 10 m³/h Catalogue head: 56 m Listed power: 2.2 kW
100GSP10T-84/6 10 84 3 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 10 m³/h Catalogue head: 84 m Listed power: 3 kW
100GSP10T-112/8 10 112 4 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 10 m³/h Catalogue head: 112 m Listed power: 4 kW
100GSP10T-168/12 10 168 5.5 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 10 m³/h Catalogue head: 168 m Listed power: 5.5 kW
100GSP10T-238/17 10 238 7.5 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 10 m³/h Catalogue head: 238 m Listed power: 7.5 kW
100GSP10T-308/22 10 308 11 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 10 m³/h Catalogue head: 308 m Listed power: 11 kW
100GSP10T-378/27 10 378 15 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 10 m³/h Catalogue head: 378 m Listed power: 15 kW
100GSP10T-420/30 10 420 18.5 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 10 m³/h Catalogue head: 420 m Listed power: 18.5 kW
100GSP10T-462/33 10 462 22 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 10 m³/h Catalogue head: 462 m Listed power: 22 kW
100GSP15T-51/4 15 51 2.2 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 15 m³/h Catalogue head: 51 m Listed power: 2.2 kW
100GSP15T-68/5 15 68 3 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 15 m³/h Catalogue head: 68 m Listed power: 3 kW
100GSP15T-79/6 15 79 4 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 15 m³/h Catalogue head: 79 m Listed power: 4 kW
100GSP15T-109/8 15 109 5.5 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 15 m³/h Catalogue head: 109 m Listed power: 5.5 kW
100GSP15T-135/10 15 135 7.5 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 15 m³/h Catalogue head: 135 m Listed power: 7.5 kW
100GSP15T-196/15 15 196 11 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 15 m³/h Catalogue head: 196 m Listed power: 11 kW
100GSP15T-258/20 15 258 15 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 15 m³/h Catalogue head: 258 m Listed power: 15 kW
100GSP15T-283/24 15 283 18.5 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 15 m³/h Catalogue head: 283 m Listed power: 18.5 kW
100GSP15T-318/27 15 318 22 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 15 m³/h Catalogue head: 318 m Listed power: 22 kW
100GSP20T-18/2 20 18 3 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 20 m³/h Catalogue head: 18 m Listed power: 3 kW
100GSP20T-35/3 20 35 4 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 20 m³/h Catalogue head: 35 m Listed power: 4 kW
100GSP20T-56/4 20 56 5.5 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 20 m³/h Catalogue head: 56 m Listed power: 5.5 kW
100GSP20T-83/6 20 83 7.5 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 20 m³/h Catalogue head: 83 m Listed power: 7.5 kW
100GSP20T-112/8 20 112 11 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 20 m³/h Catalogue head: 112 m Listed power: 11 kW
100GSP20T-150/11 20 150 15 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 20 m³/h Catalogue head: 150 m Listed power: 15 kW
100GSP20T-187/13 20 187 18.5 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 20 m³/h Catalogue head: 187 m Listed power: 18.5 kW
100GSP20T-224/14 20 224 22 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 20 m³/h Catalogue head: 224 m Listed power: 22 kW
No matching models in this series. Try a shorter model number or reset the flow group.
Reset filters Source basis: series catalogue rated-point table. Pump electrical values and drive input requirements are separate fields.
How to read this series
Choose the hydraulic duty. Then match the PM drive.
The series table describes the pump’s hydraulic reference point. It does not, by itself, specify a compatible drive or establish the electrical input for your site.
Include the local supply and the proposed drive in the same enquiry. A matching kW number alone is not enough to establish motor-drive compatibility.
Catalogue reading example
100GSP3T-105/8
Flow at the reference point 3 m³/h
Head at that point 105 m
Listed power (catalogue) 2.2 kW
Rated point listed in the catalogue. This explains one table row; it is not a recommendation for an unspecified site.
Return to the model table ↑
Material specification
Stainless-steel impellers describe one component. Confirm the casing, shaft, seals, material grades and water characteristics for the intended application; the impeller description alone does not establish corrosion or saltwater suitability.
Define the package
What should your 100GSP quotation include?
Specify what the quotation should include. Final compatibility and the exact supply scope should be confirmed in writing.
Prepare a configuration request ↗
Pump & motor Selected model, duty and electrical specification Matched PM drive Confirmed motor compatibility and input supply Installation components Cable, outlet connections and sensing requirements Technical documents Curve, dimensional drawing and wiring information Service parts Model-specific parts and the agreed service scope
Before you finalise
100GSP selection and ordering questions
Does the table complete the selection?
No. Confirm the operating range on the full performance curve, well conditions, required clearance, water characteristics and the electrical configuration.
Can the PM drive be selected by power alone?
Power alone is insufficient. Confirm the motor type, operating limits and control requirements together with the drive input and output specifications.
What should I include in a request?
The model or flow and head, destination, quantity, power supply, intended use and any required drive, accessories, documentation or inspection.
A little help goes a long way
Not sure which detail matters?
A short description, an existing model or a photo gives us a starting point. Our team can help with the next questions.
Ask our team↗
Your next step
Want a quotation for this series?
Add the models you are considering to your enquiry, or tell us the duty and the power available at the site.
Request a quote↗
These are catalogue reference points. Comparing different duties does not establish an efficiency or energy-saving advantage.