1.5 · 3.2 · 4 · 6 · 8 · 10 · 16 m³/h flow groups. Compare up to 3 models at a time.
Q and H below are the paired nominal-flow reference point from the source catalogue; they are not maximum flow and maximum head. Final selection requires the complete curve, dimensions and electrical configuration. P is the catalogue-listed power; its definition must be confirmed for the quoted model.
46 catalogue models
Q: m³/h · H: m · P: kW
100QJ models and paired catalogue reference points
Model / shortlist
Q m³/h
H m
P kW
Outlet
Details
1.5
85
0.75
40 mm / 1.5 in
Electrical reference
Source series description: 240 V single-phase (0.37–1.5 kW) / 400 V three-phase, 50 Hz. Availability and configuration for this model require confirmation.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 1.5 m³/h Corresponding head: 85 m Reference data; not a selection guarantee.
1.5
102
1.1
40 mm / 1.5 in
Electrical reference
Source series description: 240 V single-phase (0.37–1.5 kW) / 400 V three-phase, 50 Hz. Availability and configuration for this model require confirmation.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 1.5 m³/h Corresponding head: 102 m Reference data; not a selection guarantee.
1.5
146
1.5
40 mm / 1.5 in
Electrical reference
Source series description: 240 V single-phase (0.37–1.5 kW) / 400 V three-phase, 50 Hz. Availability and configuration for this model require confirmation.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 1.5 m³/h Corresponding head: 146 m Reference data; not a selection guarantee.
1.5
205
2.2
40 mm / 1.5 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 1.5 m³/h Corresponding head: 205 m Reference data; not a selection guarantee.
1.5
270
3
40 mm / 1.5 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 1.5 m³/h Corresponding head: 270 m Reference data; not a selection guarantee.
1.5
310
4
40 mm / 1.5 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 1.5 m³/h Corresponding head: 310 m Reference data; not a selection guarantee.
1.5
350
5.5
40 mm / 1.5 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 1.5 m³/h Corresponding head: 350 m Reference data; not a selection guarantee.
3.2
55
0.75
40 mm / 1.5 in
Electrical reference
Source series description: 240 V single-phase (0.37–1.5 kW) / 400 V three-phase, 50 Hz. Availability and configuration for this model require confirmation.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 3.2 m³/h Corresponding head: 55 m Reference data; not a selection guarantee.
3.2
75
1.1
40 mm / 1.5 in
Electrical reference
Source series description: 240 V single-phase (0.37–1.5 kW) / 400 V three-phase, 50 Hz. Availability and configuration for this model require confirmation.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 3.2 m³/h Corresponding head: 75 m Reference data; not a selection guarantee.
3.2
95
1.5
40 mm / 1.5 in
Electrical reference
Source series description: 240 V single-phase (0.37–1.5 kW) / 400 V three-phase, 50 Hz. Availability and configuration for this model require confirmation.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 3.2 m³/h Corresponding head: 95 m Reference data; not a selection guarantee. Confirm the model and stage-count version against the order drawing.
3.2
135
2.2
40 mm / 1.5 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 3.2 m³/h Corresponding head: 135 m Reference data; not a selection guarantee.
3.2
170
3
40 mm / 1.5 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 3.2 m³/h Corresponding head: 170 m Reference data; not a selection guarantee.
3.2
230
4
40 mm / 1.5 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 3.2 m³/h Corresponding head: 230 m Reference data; not a selection guarantee.
3.2
275
5.5
40 mm / 1.5 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 3.2 m³/h Corresponding head: 275 m Reference data; not a selection guarantee.
3.2
358
7.5
40 mm / 1.5 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 3.2 m³/h Corresponding head: 358 m Reference data; not a selection guarantee. Confirm the model and stage-count version against the order drawing.
4
42
0.75
40 mm / 1.5 in
Electrical reference
Source series description: 240 V single-phase (0.37–1.5 kW) / 400 V three-phase, 50 Hz. Availability and configuration for this model require confirmation.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 4 m³/h Corresponding head: 42 m Reference data; not a selection guarantee.
4
57
1.1
40 mm / 1.5 in
Electrical reference
Source series description: 240 V single-phase (0.37–1.5 kW) / 400 V three-phase, 50 Hz. Availability and configuration for this model require confirmation.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 4 m³/h Corresponding head: 57 m Reference data; not a selection guarantee.
4
80
1.5
40 mm / 1.5 in
Electrical reference
Source series description: 240 V single-phase (0.37–1.5 kW) / 400 V three-phase, 50 Hz. Availability and configuration for this model require confirmation.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 4 m³/h Corresponding head: 80 m Reference data; not a selection guarantee.
4
96
2.2
40 mm / 1.5 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 4 m³/h Corresponding head: 96 m Reference data; not a selection guarantee.
4
106
2.2
40 mm / 1.5 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 4 m³/h Corresponding head: 106 m Reference data; not a selection guarantee.
4
142
3
40 mm / 1.5 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 4 m³/h Corresponding head: 142 m Reference data; not a selection guarantee.
4
185
4
40 mm / 1.5 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 4 m³/h Corresponding head: 185 m Reference data; not a selection guarantee.
4
225
5.5
40 mm / 1.5 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 4 m³/h Corresponding head: 225 m Reference data; not a selection guarantee.
4
300
7.5
40 mm / 1.5 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 4 m³/h Corresponding head: 300 m Reference data; not a selection guarantee.
6
40
1.1
40 mm / 1.5 in
Electrical reference
Source series description: 240 V single-phase (0.37–1.5 kW) / 400 V three-phase, 50 Hz. Availability and configuration for this model require confirmation.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 6 m³/h Corresponding head: 40 m Reference data; not a selection guarantee.
6
50
1.5
40 mm / 1.5 in
Electrical reference
Source series description: 240 V single-phase (0.37–1.5 kW) / 400 V three-phase, 50 Hz. Availability and configuration for this model require confirmation.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 6 m³/h Corresponding head: 50 m Reference data; not a selection guarantee.
6
70
2.2
40 mm / 1.5 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 6 m³/h Corresponding head: 70 m Reference data; not a selection guarantee.
6
110
3
40 mm / 1.5 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 6 m³/h Corresponding head: 110 m Reference data; not a selection guarantee.
6
130
4
40 mm / 1.5 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 6 m³/h Corresponding head: 130 m Reference data; not a selection guarantee.
6
166
5.5
40 mm / 1.5 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 6 m³/h Corresponding head: 166 m Reference data; not a selection guarantee.
6
220
7.5
40 mm / 1.5 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 6 m³/h Corresponding head: 220 m Reference data; not a selection guarantee.
8
30
1.5
50 mm / 2 in
Electrical reference
Source series description: 240 V single-phase (0.37–1.5 kW) / 400 V three-phase, 50 Hz. Availability and configuration for this model require confirmation.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 8 m³/h Corresponding head: 30 m Reference data; not a selection guarantee.
8
40
2.2
50 mm / 2 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 8 m³/h Corresponding head: 40 m Reference data; not a selection guarantee.
8
70
3
50 mm / 2 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 8 m³/h Corresponding head: 70 m Reference data; not a selection guarantee.
8
85
4
50 mm / 2 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 8 m³/h Corresponding head: 85 m Reference data; not a selection guarantee.
8
110
5.5
50 mm / 2 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 8 m³/h Corresponding head: 110 m Reference data; not a selection guarantee.
8
168
7.5
50 mm / 2 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 8 m³/h Corresponding head: 168 m Reference data; not a selection guarantee.
10
48
2.2
50 mm / 2 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 10 m³/h Corresponding head: 48 m Reference data; not a selection guarantee.
10
60
3
50 mm / 2 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 10 m³/h Corresponding head: 60 m Reference data; not a selection guarantee.
10
80
4
50 mm / 2 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 10 m³/h Corresponding head: 80 m Reference data; not a selection guarantee.
10
108
5.5
50 mm / 2 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 10 m³/h Corresponding head: 108 m Reference data; not a selection guarantee.
10
130
7.5
50 mm / 2 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 10 m³/h Corresponding head: 130 m Reference data; not a selection guarantee.
16
36
3
50 mm / 2 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 16 m³/h Corresponding head: 36 m Reference data; not a selection guarantee.
16
52
4
50 mm / 2 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 16 m³/h Corresponding head: 52 m Reference data; not a selection guarantee.
16
63
5.5
50 mm / 2 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 16 m³/h Corresponding head: 63 m Reference data; not a selection guarantee.
16
95
7.5
50 mm / 2 in
Electrical reference
Source series description: 400 V three-phase, 50 Hz. Confirm the motor nameplate and configuration for this model. The source single-phase range ends at 1.5 kW.
Confirm for the installation
Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point
Reference flow: 16 m³/h Corresponding head: 95 m Reference data; not a selection guarantee.
No matching models in this series.
Try a shorter model number or reset the flow group.
Source basis: 100QJ catalogue model table; each model has three source Q–H points. This overview displays the nominal-flow point.
How to read this series
Read the flow and head as one operating point.
A model can have a high maximum head and still miss the flow you need. Use the paired Q–H value to understand the row, then review the full curve for your installation.
For replacement enquiries, include the existing nameplate and tell us whether you want the same duty or a change in output.
Catalogue reading example
100QJ6-40/9
Flow at the reference point
6 m³/h
Head at that point
40 m
Listed power (catalogue)
1.1 kW
Nominal-flow point transcribed from the catalogue. This explains one table row; it is not a recommendation for an unspecified site.
Pump & motorSelected model, duty and electrical specification
Control & protectionStarting, protection and control requirements
Installation componentsCable, outlet connections and sensing requirements
Technical documentsCurve, dimensional drawing and wiring information
Service partsModel-specific parts and the agreed service scope
Before you finalise
100QJ selection and ordering questions
Does the table complete the selection?
No. Confirm the operating range on the full performance curve, well conditions, required clearance, water characteristics and the electrical configuration.
Are all voltage versions available for every model?
The source includes series-level electrical descriptions. Confirm the actual voltage, phase and frequency for the individual motor and control configuration.
What should I include in a request?
The model or flow and head, destination, quantity, power supply, intended use and any required drive, accessories, documentation or inspection.
A little help goes a long way
Not sure which detail matters?
A short description, an existing model or a photo gives us a starting point. Our team can help with the next questions.