To size a solar water pump, start with the litres you need each day, then check whether a proposed pump and solar system can deliver that volume at your actual pumping head in the demanding months. The borehole must support the pumping rate, and the tank must bridge the hours when water is needed but pumping is low or stopped.
A pump advertised at a certain litres-per-hour figure does not automatically supply that flow all day. Solar input changes, the water level may fall during pumping, and the tank may need to recover after a cloudy day.
If you are starting without technical records, gather three things first: your location, the water used on a busy day, and where the water must go. Existing tank sizes, water-meter readings and a borehole test report are useful additions. Unknown measurements can be filled in during selection.
1. Put a daily volume beside each water use
Write down household or staff use, livestock, irrigation and cleaning separately. Use measured consumption where available. For seasonal uses, record the busy season as well as the quieter months; an annual average can hide the period when the system struggles.
For example, suppose a smallholding needs the following amounts on a chosen design day. These are assumed site requirements, not recommended allowances per person, animal or hectare.
| Water use | Assumed daily volume |
|---|---|
| Household and staff | 1,500 L |
| Livestock | 2,000 L |
| Garden irrigation | 4,000 L |
| Cleaning | 500 L |
| Total | 8,000 L/day = 8 m³/day |
The example assumes no additional loss between pumping into storage and these uses. At a real site, account for known distribution losses, treatment water or other uses once, at the correct point in the water balance. If future demand is expected, identify the extra use instead of quietly adding several overlapping safety factors.

Keep daily volume separate from the busiest hour. Livestock may drink together, and irrigation may run in a short window. A tank can let a borehole pump fill steadily while outlets draw water faster for a while. The tank outlet, downstream pump if needed, and pipework must still deliver the required flow and pressure. Direct solar pumping to outlets needs a separate check of those simultaneous demands.
2. Choose the demanding month, not a national sunshine average
A dry month can combine high water demand with a lower pumping water level. Another month may have less sunlight but also much less irrigation. Compare monthly demand, solar availability and head together to find the period with the smallest supply margin.
This is also why a country-wide statement such as “South Africa has enough sun” cannot size a particular installation. Give the supplier the actual location, seasonal operating pattern and known shading. Grundfos describes this comparison through its sizing tool’s critical-month approach in its solar pumping selection lesson.
Peak sun hours are not hours of constant pump flow
Peak sun hours express daily solar energy as an equivalent number of hours at 1,000 W/m². They do not say that the pump will run at full output for that many clock hours. The definition is explained in Penn State’s solar-resource lesson.
A solar pump may deliver slowly in the morning, more near midday and less later on. At some combinations of available power and head, it may deliver no water. Panel capacity, the pump, its controller and the hydraulic conditions all affect that daily pattern.
Use location-specific monthly solar data in the proposed system’s sizing calculation. Then ask for the expected daily water volume and, where timing or borehole limits matter, the hourly flow profile. A monthly average estimate still needs a separate plan for cloudy sequences.
3. Turn litres per day into a preliminary flow target
For a first screening calculation, divide the daily volume by an assumed pumping allowance:
Preliminary flow (m³/h) = daily volume (m³/day) ÷ assumed pumping hours (h/day).
For the 8 m³/day example, assume five hours at a steady target flow:
8 ÷ 5 = 1.6 m³/h, or about 26.7 L/min.
That five-hour allowance is an explicit planning assumption. It is neither a local solar-resource measurement nor proof that a solar pump will deliver a flat 1.6 m³/h for five hours. If only four equivalent hours were available, the same calculation would give 2.0 m³/h; with six, it would give about 1.33 m³/h.
Use this result to begin comparing duties. Complete the selection with the daily delivery predicted for the actual equipment and site. LORENTZ’s S1 sizing guidance illustrates the kind of output to request: monthly average daily water delivery and hourly flow for the entered location, head, pipework and solar arrangement. Its results apply to the specified S1 configuration, not automatically to another pump.
Pair the flow with the correct head
Suppose the water is being pumped into an open tank, with these assumed conditions at the 1.6 m³/h screening flow:
- Pumping water level: 35 m below the borehole’s ground reference.
- Open discharge into the tank: 8 m above that same reference.
- Pipe and fitting losses: 7 m, already calculated for the route and flow.
The preliminary total dynamic head is 35 + 8 + 7 = 50 m. There is no additional delivery-pressure requirement at this open discharge. If the borehole pump must feed a pressurised line instead, include that requirement.
The screening duty is therefore 1.6 m³/h at 50 m TDH. It is not “a pump for a 50 m deep borehole.” The total dynamic head guide explains the measurement points. If the selected flow or pumping water level changes, recalculate the losses and head before accepting the proposal.
Check the borehole during the strongest pumping hours
Assume the borehole test supports a recommended maximum abstraction rate of 2.0 m³/h under a stated operating schedule. The 1.6 m³/h screening figure is below that rate, but this alone does not clear the solar system: its midday flow could be higher.
Ask whether the proposed system stays within the borehole’s tested rate, pumping-level limits and recovery requirements throughout the operating day. A daily volume of 8 m³ does not prove that every way of extracting those 8 m³ is sustainable. Flow limiting, a different pump or a different operating schedule may be needed; verify the resulting daily yield again. The World Bank’s Solar Pumping: The Basics explains the role of pumping tests and seasonal water-level changes in selection.
4. Size storage around when water is used
If most pumping happens in daylight but water is also used before sunrise or after sunset, plot the withdrawals against the incoming water. The largest accumulated shortfall tells you how much usable storage the schedule requires, before adding the separately agreed reserve.
Usable storage is the volume between the normal high level and the lowest level from which the system can still deliver water. A tank’s nominal capacity can include water below the outlet or other volume you cannot use. Gravity supply also loses pressure as the level falls; where a booster is needed, it needs an adequate power supply at the time of use.

For a simple autonomy requirement, two full days with no pumping at 8,000 L/day require 16,000 L of usable water. That is a specified scenario, not a universal recommendation for two days of storage. A different backup supply, restricted irrigation schedule or reliability target changes the requirement. Check the combined daily schedule and reserve without counting the same shortfall twice.
Check how the tank recovers after a cloudy day
A tank can cover a temporary shortage, but the system needs spare delivery capacity to refill it while normal use continues. Consider this separate, assumed water balance, starting with enough stored water:
- On a cloudy day, the pump supplies 3 m³ and the site uses 8 m³. Storage falls by 5 m³.
- On a recovery day, assume the selected system can supply 12 m³ while the site still uses 8 m³. Storage gains 4 m³.
- Restoring the 5 m³ deficit takes 5 ÷ 4 = 1.25 equivalent recovery days at that daily balance. This is a daily-balance estimate; use the hourly supply and withdrawal pattern to find when the reserve is fully restored.

The assumed 12 m³/day recovery output must be demonstrated separately. It does not follow from the earlier 1.6 m³/h screening duty. With abstraction capped at 2.0 m³/h, delivering 12 m³ takes at least six actual pumping hours, and longer if flow is lower for part of the day. The solar profile, borehole performance and head must allow it.
If a system can only deliver the normal 8 m³/day while the site continues using 8 m³/day, it has no surplus to rebuild that reserve. Options include a verified increase in delivery, temporary reduction of non-essential demand or a suitable backup source. A larger tank alone cannot correct a continuing supply deficit. The USDA NRCS solar water-pumping design guide explains storage sizing through daily production and demand balances.
5. Send a short brief that a supplier can size against
For a first enquiry, your location, busy-day volume and intended destination are enough to start the conversation. Add existing records and photos; mark missing data as unknown. Use the fuller list below to complete the design with the installer or supplier.
| Selection input | What to provide |
|---|---|
| Site and season | Location, months of operation and nearby shading |
| Daily demand | Litres/day by use, with high-demand months and planned growth |
| Use times | Morning/evening withdrawals and any direct pressure or irrigation requirement |
| Borehole evidence | Test rate, pumping water level, test duration, recovery and recommended operating limits |
| Delivery route | Tank entry elevation or outlet pressure, pipe lengths, internal diameters and important fittings |
| Storage | Usable capacity, level limits, required reserve and backup supply |
| Existing equipment | Pump/controller labels and solar information, if equipment must be retained |
Request a proposal that states the chosen pump and controller, assumed solar configuration, head and flow limits, and expected daily delivery for the relevant months. Ask it to show both the normal supply target and the agreed recovery or backup scenario. This makes two proposals comparable; motor kW and a maximum-flow headline do not.
The QDD solar water-pumping page outlines system-planning inputs. You can also send the information you already have through pump selection support, then identify the measurements still needed for a final equipment choice.
After commissioning, compare daily delivered volume and tank-level recovery under recorded weather and use conditions. Include the early or late outlets that matter to the user. One strong midday flow reading is useful, but the practical result is enough water across the agreed daily schedule, with storage recovering as planned.