A water pump can keep running briefly after you close the last tap. It may still be bringing the pipes and pressure tank back up to pressure, or filling a separate storage tank. If it runs well past its usual stopping point, find out what should tell that particular pump to stop. That might be a pressure switch, a tank level switch or an electronic controller looking for little or no flow.
If the pump has lost its water supply, is making an unusual noise, is overheating or is pushing pressure above its normal range, stop it with its external control or a safely accessible isolator. Keep clear of wet electrical equipment. If the pump keeps running well beyond its normal stopping point with no known water use, shut it down safely and arrange a check. Prolonged running against a closed outlet can build heat and damage the pump.
Find out which pump is running
Use the controller’s motor status, if it has one, or the sound of an accessible surface pump. A power light can stay on when the motor is idle. If you have both a borehole pump and a booster, check which controller shows a run indication. The two pumps do different jobs and can run at different times.

In a system with a vented storage tank, the borehole pump fills the tank. If it is controlled by tank level, it can continue filling after everyone has finished using water. A float switch or level sensor should call for a stop when the water reaches the configured high level. If the tank uses a mechanical float valve, that valve closes the inlet and the pump’s own control must handle the stop. Meanwhile, a separate booster supplies the taps from the tank and responds to pressure or demand on the house side.
If the tank level rises towards its usual stopping point and the filling pump then stops, that is consistent with normal refill. If the tank reaches its usual full level and the pump continues, or water comes from the overflow, stop the filling pump safely and have the level control checked. If the pump runs without the level rising, note whether water is leaving the tank elsewhere. If there is little or no visible inflow, the installer will need to check the source and the filling line as well as the level control. Use an existing level indicator or a view from ground level. Leave the tank lid, wiring and float assembly alone.
In a direct borehole supply system, the borehole pump itself may build pressure for the taps. Follow the pressure switch or electronic controller branch below according to the controls on that pump.
If you have a pressure switch, watch where the pressure goes
A conventional pressure switch starts the pump at a lower pressure, called cut-in, and stops it at a higher pressure, called cut-out. After the last tap closes, the pump may still need to push water into the pressure tank before the switch reaches cut-out. A short run that ends at the usual stopping pressure can be normal.
If a gauge is already fitted and the system is otherwise behaving safely, look at it after normal water use ends. Use the recorded cut-out from commissioning or a known previous normal cycle. A pump’s maximum pressure rating and a switch’s factory label do not establish the current installed cut-out. If you cannot confirm that setting, record the highest pressure you actually see and whether it rises, levels off or falls.

Pressure rises, then levels off below cut-out
The switch has a reason to keep asking for the pump to run if the pressure at its sensing point is below cut-out. There are two questions to work through. Is water still leaving the pressurised system? Can the pump deliver enough head to reach the required pressure under today’s supply conditions? Head is commonly expressed in metres of water. In a borehole system, the pump has to provide enough head to lift water from the pumping water level and still build pressure at the switch.
Start with water use you can see or hear. A toilet cistern can keep refilling, an irrigation zone may still be on, or an appliance may be drawing water behind a closed kitchen tap. Look for water at accessible pipe joints and outlets. A concealed leak may also take enough flow to hold the pressure below cut-out. Seeing no water on the ground leaves that possibility open.
If the pump cannot build pressure as it used to, useful clues include weaker flow at several outlets, a low feed tank, or the fault starting after a dry period. A surface pump may have an inlet problem or have lost prime. A borehole pump may have to lift water from a lower pumping level. A worn pump or a leak in the delivery pipe can also reduce the pressure seen at the house. If the fault began after a pump, switch or controller was replaced, have the installer compare the pump’s available head with the installed stop setting and actual water level. Pentair’s pump and controller troubleshooting manual lists loss of pressure, leaks and control faults as separate checks.
Suppose a system used to stop at 3.5 bar and now sits at 2.8 bar on the same gauge while the pump runs. Those are example readings. The useful finding is that the system can no longer reach its former stopping pressure under the conditions observed. Report both numbers and any change in water use or supply. The numbers alone cannot identify a bad switch or prove the pump needs replacing.
Pressure reaches the known cut-out but the motor keeps running
If an accurate gauge near the switch shows the expected cut-out and the motor continues, ask the installer to check whether the switch senses the same pressure as the gauge and whether the stop signal actually removes power from the motor. A blocked sensing passage can leave the switch responding to a different pressure from the one on the gauge. Stuck contacts, a motor starter fault or a manual override can also keep the motor energised. A gauge in another part of the system or an inaccurate gauge can make a pressure problem look like a control fault.
For example, a reading that passes the usual 3.5 bar stop point and keeps climbing calls for stopping the pump safely. Record the reading only if it is already visible. Leave switch covers closed and have the stop circuit and pressure verified before running the system again. Changing the cut-out setting before finding the cause can hide the symptom or exceed equipment limits.
The pump stops, then pressure falls and it starts again
That pattern gives a different clue. The pump was able to stop on that cycle, and pressure dropped again afterwards. If nobody is using water, an installer can check for unnoticed demand, a leak or backflow through a check valve, which is intended to keep water moving one way. A pressure tank with very little usable drawdown, the water it can supply between stop and start, can make a small loss show up as frequent restarts. Report the stop and restart pattern as well as any pressure readings. See the guide to pumps that repeatedly start and stop for that symptom.
If you have an electronic controller, read its run status
An electronic pressure and flow controller can start the pump on a fall in pressure and wait for flow to drop below its stop threshold before it switches off. Some units also require a pressure condition or use a different mode with a pressure tank. A small leak or ongoing cistern refill may keep enough water moving to hold the pump on. A delay after flow drops may also be normal. Check the stop behaviour in the instructions for the exact model. If the display shows flow while all known outlets are closed, record the reading and check for continuing use. If the reading persists without an obvious outlet, the installer can establish whether there is actual flow or an issue with the controller’s flow detection. The controller comparison guide explains how to tell these arrangements apart.
A variable-speed controller can keep the gauge close to the requested pressure while the motor continues to run slowly. Its pressure target tells it how fast to run. Its low-demand stop or sleep function decides when it can stop. Some controllers infer whether water is still being used by changing speed and watching the pressure response. For example, the Grundfos CU 301 instructions describe how the controller checks for flow and fills the diaphragm tank before stopping when demand has ended. Use your own model’s stop conditions and delay when assessing its behaviour.
Record the displayed pressure, run or sleep status, speed or flow if shown, and any alarm code. Note whether the display shows manual mode or override. If the display and an existing nearby gauge disagree significantly under steady conditions, report both. The installer can check the gauge, sensor and controller configuration against the manual. If the behaviour began after a controller replacement or settings change, mention that date. Avoid changing sensor scaling, stop settings or minimum speed just to see whether the motor stops.
What the observation tells you
Start with the row that fits your system. Where the normal stop condition is unknown, record the trend and the model number so it can be checked against the installation details.
| What you observe | What to check next |
|---|---|
| Borehole pump fills a vented tank after the taps close. | See whether the level rises and filling stops at its usual high level. |
| Filling continues at full level, or the tank overflows. | Stop filling safely and ask for the high-level control to be checked. |
| Pressure stalls below a known cut-out. | Look for continuing water use. Report supply changes and the highest reading. |
| Pressure reaches or passes cut-out and the pump still runs. | Stop safely if pressure keeps climbing. Ask for the sensing and stop circuit to be checked. |
| The controller shows flow or low speed with no known use. | Record the status and check the model’s stop conditions and delay. |
| Pump stops, pressure falls, then the pump restarts. | Report cycling. Check for unnoticed use and ask about leakage, backflow and tank drawdown. |
What to send your installer
You can make a useful first report with a photo of the outside of the controller, a model number if it is visible, and a short description of what changed. Include which pump is running, what it supplies, how long you have observed it running, and whether the problem followed a dry spell, power interruption or equipment change. If a gauge or display is available, note the reading at tap closure and where it settles. For a filling pump, describe whether the level rises or the overflow runs. Skip any observation that would require restarting a pump you have already stopped for safety.
Ask the installer to confirm the expected stop condition and demonstrate a normal stop after ordinary water use. For a tank-filling fault, ask them to verify that the pump stops at the configured high level. If you need QDD to help identify a QDD pump or controller, share the external nameplate details and a description of how the pump is used. Those details help establish which equipment instructions and operating limits apply.