You want the borehole pump to fill a storage tank while you are away. A controller advertised with “dry-run protection” sounds reassuring. But what makes it stop, and what tells it that pumping can safely resume?
Borehole pump dry-run protection commonly uses either a source-water level input or electrical motor-load monitoring. A suitable system must match the pump, motor and controller, and its restart behaviour must suit the water source. A tank-full float serves a separate purpose: it stops filling when the receiving tank is full.
If your pump is already running without delivering water, stop it rather than leaving it on while choosing a protection device. Start with borehole pump running but no water. The guide below is for choosing and checking protection before unattended operation.
Protect the water source and control the receiving tank
Picture two situations. The storage tank is almost empty, but pumping has drawn the borehole water level too low. The tank still needs water; that demand must not override source-water protection.
Now reverse it: the borehole has sufficient water, but the storage tank is full. There is no reason to keep filling it.
A borehole-to-tank installation therefore needs to address both questions:
- Is the source-water protection allowing operation?
- Does the receiving tank need water?
Even when both answers are yes, the controller may still be waiting for a restart delay, adequate power or another fault to clear. “Permitted to run” does not mean “starts immediately.”

LORENTZ documents these as separate functions: its dry-run protection accessory responds to water at the source, while its tank-full switch responds to the receiving tank. Those examples explain the distinction; their settings and connections are specific to that equipment.
If a second pump draws water from the storage tank to supply a house, that pump has a different source: the tank. Its low-water protection needs a separate assessment.
What does each protection method actually detect?
A level sensor checks water at the source
A suitably selected level input tells the controller whether water has reached a defined position. Depending on the equipment, this may use a dedicated low-water probe, conductive electrodes, a float or another compatible level sensor.
This is useful when you want the stop condition tied to an actual water level. It still does not tell you the borehole’s sustainable yield, and a single switching point does not provide a continuous depth reading.
The practical details matter. A moving float needs room to travel without catching on the casing, pipes or cables. Conductive electrodes need water and a controller that work within the specified sensing range; “probe” does not mean every device uses the same principle. For example, Carlo Gavazzi’s conductive level-controller data sheet specifies sensitivity, electrode arrangements and cable limits.
The installer should choose the stopping level using the pump’s submergence requirements and the installation conditions. Also check motor cooling: having water around a motor does not necessarily provide enough flow past it. Some installations need a cooling sleeve to direct that flow. There is no reliable universal instruction to put every probe a fixed distance above every pump.
Motor-load monitoring looks for an electrical change
When a pump stops moving water normally, its motor load can change. A compatible protection device can use that change to stop the pump without a separate water-level cable down the borehole.
The word load matters. Some devices monitor power; others use current or a controller-specific method. A generic “set the current to this percentage” instruction is not interchangeable across them.
The Franklin Pumptec family illustrates why the full model matters: its variants have different motor compatibility and calibration requirements. Where a device learns normal load, that learning must take place under the manufacturer’s specified, healthy operating conditions.
An underload alarm is a clue, not a water-level measurement. Depending on the equipment, low load may also reflect an obstructed intake, a mechanical problem, an unsuitable setting or another abnormal condition. The controller cannot be assumed to know the exact depth of water in the borehole.

Pressure and flow devices watch the delivery side
Some controllers use low pressure, lack of flow or a combination of signals as part of their protection. They must be selected for the actual arrangement, including whether the pump supplies an open tank or a pressurised system.
Neither an outlet pressure reading nor a flow signal directly measures the source-water level. Ask what happens during normal startup, low demand and loss of supply, and which conditions the device can distinguish. A device described only as an “automatic pump controller” is not enough information to confirm protection.
Choose around the installation you already have
If the pump has built-in protection, start with its manual. Confirm which motor and drive it covers, whether the function is active, and whether it needs an external sensor. Adding another control box without checking the existing system can create conflicting start and stop commands.
If you can install a suitable source-level sensor, ask for the complete sensing arrangement. That includes the sensor, cable, compatible input and stop/recovery logic. Check space, water conditions and future access for inspection. Buying a probe by itself does not establish how the pump will respond.
If another cable down the borehole is impractical, investigate load-based protection matched to the motor and drive. Supply voltage and kW alone do not establish compatibility. Single-phase motor types, three-phase motors, variable-speed drives and permanent-magnet motors can require different solutions. With a solar pumping system, confirm the protection method across its intended operating speeds.
If the pump repeatedly stops and retries, review the water supply as well as the control. Protection cannot increase borehole yield. Persistent trips may require investigation of the source, pumping rate or filling schedule; repeated resets do not demonstrate a healthy system. If the main symptom is rapid cycling, use the separate guide to a water pump that keeps starting and stopping.
Agree on what happens after a dry-run stop
For an unattended installation, this is often the most useful part of the specification. Ask the supplier to explain the sequence in ordinary language:
- What stops the pump? A particular low-water input, a detected load change or another defined condition?
- What allows recovery? Water returning to a sensor, a permitted retry, a manual reset or a combination?
- When can it try again? Which waiting period or other start conditions apply?
- What happens if the fault continues? Does it keep trying, lock out or provide an alarm, and who will notice?
Level-based systems may wait after water returns to a sensor. Load-based systems may make a controlled retry and then assess the running load again. The exact sequence belongs to the controller’s documented design.
A timer expiring is not evidence that the borehole has recovered. Equally, water returning briefly to a sensor does not prove the source can sustain the next pumping run. Waiting times should follow the equipment requirements and verified source behaviour, not a universal number copied from another installation.
Where separate stop and recovery levels are used, the level gap can help prevent repeated switching as water moves around one point. That is different from a time delay. Ask which approach the proposed system actually uses.
What to check before leaving the pump unattended
Ask the installer to demonstrate the protection using the manufacturer’s permitted test method. There is no need to deliberately pump the borehole dry to prove that a control input works.
The handover should establish that the source-protection input or built-in protection is enabled, a stop request reaches the correct pump, and the tank-full input works independently. Confirm the documented restart sequence as well as the initial stop.
Also ask what the system does if a sensor is disconnected, its cable is damaged or a float becomes stuck. Do not assume every sensor fault produces a safe stop. The answer depends on the sensor, input configuration and controller.
Record the actual pump, motor, drive and protection-device models, the approved settings, and what each alarm means. Dry-run protection does not replace the motor’s other required electrical protection. Keep installation and electrical testing with a qualified person using the equipment instructions.
Send enough information for a useful recommendation
You do not need a complete engineering file to start an enquiry. Send clear photos of the pump or motor nameplate and the existing controller label, then say:
- Whether the pump fills a storage tank or supplies outlets directly.
- Whether it needs to operate unattended.
- What level sensors or protection devices are already fitted.
- Any known pumping water-level measurements, low-water events or alarm messages.
If a measurement is unknown, say so. It is more useful than guessing.
QDD’s control-panel requirements page and level and pressure sensing requirements page help frame that enquiry. Ask for the proposed protection method, compatible inputs and restart behaviour to be confirmed for the quoted configuration.
Common questions
Can one tank float also protect the borehole pump from dry running?
A float monitoring the receiving tank does not know the water level in the borehole. It can control filling demand, but source-water protection remains a separate requirement. The same float may also be unsuitable for the space or conditions inside the borehole.
Is thermal protection enough?
Do not treat a motor temperature trip as a substitute for dry-run protection. It responds to a different condition. Confirm the pump’s documented dry-run method and its required cooling conditions rather than waiting for overheating.
Does a dry-run or underload alarm mean the borehole is empty?
Not necessarily. Read the alarm definition for that controller. A level input reports a condition at its sensing position; a load alarm reports abnormal electrical behaviour. Either can require inspection of the sensor, installation or pump before concluding that the source has run out of water.