GSR permanent-magnet borehole pumps
Permanent-magnet borehole pumps with plastic impellers. Select the hydraulic duty, then confirm a compatible motor-drive configuration.
29
catalogue models
4
flow groups
2.2–18.5
catalogue-listed kW
GSR Catalogue reference Exterior Catalogue cutaway
View catalogue cutaway
Model finder
Compare GSR models by flow, head and power. 4 · 6 · 10 · 12 m³/h flow groups. Compare up to 3 models at a time.
Q and H below are the source-catalogue values for each model, not maximum flow and maximum head. P is the catalogue-listed power. Share your required flow, head and power supply if you would like help choosing a model.
All 29 catalogue models are listed below. Enable JavaScript to filter, compare or prepare a shortlist.
29 catalogue models
Q: m³/h · H: m · P: kW
GSR models and source-catalogue reference values Model / shortlist Q m³/h H m P kW Outlet Details 100GSR4T-135/7 4 135 2.2 1½" / 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 4 m³/h Catalogue head: 135 m Listed power: 2.2 kW
100GSR4T-175/9 4 175 3 1½" / 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 4 m³/h Catalogue head: 175 m Listed power: 3 kW
100GSR4T-210/11 4 210 4 1½" / 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 4 m³/h Catalogue head: 210 m Listed power: 4 kW
100GSR4T-280/14 4 280 5.5 1½" / 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 4 m³/h Catalogue head: 280 m Listed power: 5.5 kW
100GSR4T-389/20 4 389 7.5 1½" / 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 4 m³/h Catalogue head: 389 m Listed power: 7.5 kW
100GSR4T-450/26 4 450 11 1½" / 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 4 m³/h Catalogue head: 450 m Listed power: 11 kW
100GSR6T-90/5 6 90 2.2 1½" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 6 m³/h Catalogue head: 90 m Listed power: 2.2 kW
100GSR6T-130/7 6 130 3 1½" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 6 m³/h Catalogue head: 130 m Listed power: 3 kW
100GSR6T-165/9 6 165 4 1½" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 6 m³/h Catalogue head: 165 m Listed power: 4 kW
100GSR6T-215/12 6 215 5.5 1½" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 6 m³/h Catalogue head: 215 m Listed power: 5.5 kW
100GSR6T-295/16 6 295 7.5 1½" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 6 m³/h Catalogue head: 295 m Listed power: 7.5 kW
100GSR6T-360/20 6 360 11 1½" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 6 m³/h Catalogue head: 360 m Listed power: 11 kW
100GSR6T-448/26 6 448 15 1½" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 6 m³/h Catalogue head: 448 m Listed power: 15 kW
100GSR10T-48/3 10 48 2.2 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 10 m³/h Catalogue head: 48 m Listed power: 2.2 kW
100GSR10T-80/5 10 80 3 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 10 m³/h Catalogue head: 80 m Listed power: 3 kW
100GSR10T-118/7 10 118 4 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 10 m³/h Catalogue head: 118 m Listed power: 4 kW
100GSR10T-156/9 10 156 5.5 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 10 m³/h Catalogue head: 156 m Listed power: 5.5 kW
100GSR10T-205/12 10 205 7.5 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 10 m³/h Catalogue head: 205 m Listed power: 7.5 kW
100GSR10T-273/16 10 273 11 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 10 m³/h Catalogue head: 273 m Listed power: 11 kW
100GSR10T-330/20 10 330 15 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 10 m³/h Catalogue head: 330 m Listed power: 15 kW
100GSR10T-485/24 10 485 18.5 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 10 m³/h Catalogue head: 485 m Listed power: 18.5 kW
100GSR12T-45/3 12 45 2.2 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 12 m³/h Catalogue head: 45 m Listed power: 2.2 kW
100GSR12T-60/4 12 60 3 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 12 m³/h Catalogue head: 60 m Listed power: 3 kW
100GSR12T-75/5 12 75 4 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 12 m³/h Catalogue head: 75 m Listed power: 4 kW
100GSR12T-105/7 12 105 5.5 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 12 m³/h Catalogue head: 105 m Listed power: 5.5 kW
100GSR12T-135/9 12 135 7.5 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 12 m³/h Catalogue head: 135 m Listed power: 7.5 kW
100GSR12T-180/12 12 180 11 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 12 m³/h Catalogue head: 180 m Listed power: 11 kW
100GSR12T-240/16 12 240 15 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 12 m³/h Catalogue head: 240 m Listed power: 15 kW
100GSR12T-295/20 12 295 18.5 2" View details + Pump table: 380 V. Drive input, output and frequency to confirm. Electrical reference Pump table: 380 V. Drive input, output and frequency to confirm.
Confirm for the installation Maximum assembly diameter, setting conditions, cable, materials and the required accessories.
Reference point Catalogue flow: 12 m³/h Catalogue head: 295 m Listed power: 18.5 kW
No matching models in this series. Try a shorter model number or reset the flow group.
Reset filters Source basis: series catalogue rated-point table. Pump electrical values and drive input requirements are separate fields.
How to read this series
Choose the hydraulic duty. Then match the PM drive.
The series table describes the pump’s hydraulic reference point. It does not, by itself, specify a compatible drive or establish the electrical input for your site.
Include the local supply and the proposed drive in the same enquiry. A matching kW number alone is not enough to establish motor-drive compatibility.
Catalogue reading example
100GSR6T-90/5
Flow at the reference point 6 m³/h
Head at that point 90 m
Listed power (catalogue) 2.2 kW
Rated point listed in the catalogue. This explains one table row; it is not a recommendation for an unspecified site.
Return to the model table ↑
Define the package
What should your GSR quotation include?
Specify what the quotation should include. Final compatibility and the exact supply scope should be confirmed in writing.
Prepare a configuration request ↗
Pump & motor Selected model, duty and electrical specification Matched PM drive Confirmed motor compatibility and input supply Installation components Cable, outlet connections and sensing requirements Technical documents Curve, dimensional drawing and wiring information Service parts Model-specific parts and the agreed service scope
Before you finalise
GSR selection and ordering questions
Does the table complete the selection?
No. Confirm the operating range on the full performance curve, well conditions, required clearance, water characteristics and the electrical configuration.
Can the PM drive be selected by power alone?
Power alone is insufficient. Confirm the motor type, operating limits and control requirements together with the drive input and output specifications.
What should I include in a request?
The model or flow and head, destination, quantity, power supply, intended use and any required drive, accessories, documentation or inspection.
A little help goes a long way
Not sure which detail matters?
A short description, an existing model or a photo gives us a starting point. Our team can help with the next questions.
Ask our team↗
Your next step
Want a quotation for this series?
Add the models you are considering to your enquiry, or tell us the duty and the power available at the site.
Request a quote↗
These are catalogue reference points. Comparing different duties does not establish an efficiency or energy-saving advantage.